SENSE 100 - Silicon nitride AFM probe

SENSE 100 60deg v2.png
SENSE 100 Tip v2.png
DNA Origami - Website Image.png
Porous material Freiburg - Website Image.png
Purple Membrane - Cytoplasmic Side - Website.png
SENSE 100 60deg v2.png
SENSE 100 Tip v2.png
DNA Origami - Website Image.png
Porous material Freiburg - Website Image.png
Purple Membrane - Cytoplasmic Side - Website.png

SENSE 100 - Silicon nitride AFM probe

£450.00

Benefit from high quality imaging with our pack of 10 general purpose silicon nitride AFM probes, suitable for imaging soft samples using contact or AC mode in either air or liquid. They feature a sharp silicon tip integrated onto a silicon nitride cantilever with a gold reflective backside coating.

Spring constant: 0.1 N/m

Resonant frequency: 100 kHz

Quantity:
Add To Cart

For bulk orders, quotation requests, or to pay in Euros/USD:


High quality imaging every time…

“We used the Sense 100 probes to image porous amphiphilic block-copolymer morphologies with a Cypher ES in intermittent-contact mode in air and in water. We were impressed by the good quality of the images, in particular the great contrast of the phase images. The Sense 100 probes proved their capability to image soft samples and could reveal the details of porous structures with high precision!” - Dr. Bizan N. Balzer, University of Freiburg, Germany

“The Sense 100 probes fill a very important niche for biological AFM - soft, and relatively small cantilevers that allow gentle imaging and low-noise force data at reasonable scan rates, but are still large enough to be used with conventional AFMs. They also have a tip that is tall enough to work with topographic samples (e.g. live bacteria) and sharp enough to image biomolecules.” - Dr Nic Mullin, University of Sheffield, UK

Cantilever Specifications

Parameter Nominal Range
Spring constant (N/m) 0.1 0.07 - 0.12
Resonant frequency (kHz) 100 80 - 120
Shape Rectangular
Length (µm) 38 37 - 39
Width (µm) 16 15 - 17
Thickness (µm) 0.2 0.18 - 0.22
Material Silicon nitride

NB. Nominal values for spring constants and resonant frequencies are calculated using well known formulae and based on expected probe dimensions. The ranges are calculated using measured dimensions.

Tip Specifications

Parameter Nominal Range
Radius (nm) 5 < 10
Height (µm) 7 5 - 8
Shape Tetrahedral
Material Silicon (n-type, Antimony) with protective SiN neck

Coating

Frontside/Tip

  • None

Backside/Reflective

  • 5 nm Ti

  • 40 nm Au

Disclaimer

At NuNano we continually strive to develop and improve our products. Consequently, Nu Nano Ltd reserves the right to change specifications without notice.

Please see our privacy policy for how we use your data.